MAX35104ETL+ by Analog Devices

Gas Flow Meter SoC


The MAX35104 is a gas flow meter system-on-chip (SoC) targeted as an analog front-end solution for the ultrasonic gas meter and medical ventilator markets. With a time measurement accuracy of 700ps and automatic differential time of flight (TOF), the device makes for simplified computation of gaseous flow. Power consumption is the lowest available with ultra-low 62µA time-of-flight measurement and 125nA duty-cycled temperature measurement. Multi-hit (up to six per wave) capability with stop-enable windowing allows the device to be fine-tuned for the application. Internal analog switches, a configurable three-stage integrated operational amplifier chain amplifier, and an ultra-low input offset comparator provide the analog interface and control for a minimal electrical bill of material solution. A programmable high-voltage (up to 30V) pulse launcher provides up to 19dB of transducer launch amplitude adjustment to compensate for transducer aging and temperature, pressure, humidity affects. Early edge detection ensures measurements are made with consistent wave patterns to greatly improve accuracy and eliminate erroneous measurements. Built-in arithmetic logic unit provides TOF difference measurements and programmable receiver hit accumulators to minimize the host microprocessor access. For temperature measurement, the device supports a single 2-wire PT1000 platinum resistive temperature detector (RTD) or NTC thermistor. A simple 4-wire SPI interface allows any microcontroller to effectively configure the device for its intended measurement.

Where to Buy

Prices starting from US$9.56

Distributor Stock
Logo for Newark
Newark Electronics
from US$14.20
0
in stock
Buy Now
Logo for element14 Singapore
element14
from US$15.03
0
in stock
Buy Now
Logo for Analog Devices
Analog Devices
from US$9.56
0
in stock
Buy Now
Logo for Farnell UK
Farnell
from US$13.89
0
in stock
Buy Now
Buy Now

Features

High Accuracy Flow Measurement for Billing and Leak Detection Time-to-Digital Accuracy Down to 700ps Measurement Range Up to 8ms 2 Channels: Single-Stop Channel
Time-to-Digital Accuracy Down to 700ps Measurement Range Up to 8ms
2 Channels: Single-Stop Channel
High Accuracy Temperature Measurement for Precise Flow Calculations One 2-Wire Sensor: PT1000, PT500 RTD, and Thermistor Support
One 2-Wire Sensor: PT1000, PT500 RTD, and Thermistor Support
Maximizes Battery Life with Low Device and Overall System Power Ultra-Low 62µA TOF Measurement and 125nA Duty-Cycled Temperature Measurement Event Timing Mode with Randomizer Reduces Host µC Overhead to Minimize System Power Consumption 2.3V to 3.6V Single-Supply Operation
Ultra-Low 62µA TOF Measurement and 125nA Duty-Cycled Temperature Measurement
Event Timing Mode with Randomizer Reduces Host µC Overhead to Minimize System Power Consumption
2.3V to 3.6V Single-Supply Operation
High Integration Solution Minimizes Parts Count and Reduces BOM Cost Built-In Real-Time Clock Small, 5mm x 5mm, 40-Pin TQFN Package -40°C to +85°C Operation
Built-In Real-Time Clock
Small, 5mm x 5mm, 40-Pin TQFN Package
-40°C to +85°C Operation

Specifications

Sensing Element RTDUltrasonic Piezoelectric TransducerUltrasonic Transducer
PGA Gain 10 to 29.95 (16 gains)
Calibration Method External microcontroller
Output Type Digital
ICC (mA) (typ) 0.006
Interface SPI
VSUPPLY (V) 2.3 to 3.6
Package/Pins TQFN/40
BudgetaryPrice (See Notes) 7.73

Last 6 months Inventory & Pricing History



MAX35104ETL+ Special Function by Analog Devices

GAS FLOW METER SOC 2.3V-3.6V TQFN-40

Status: Unknown
Series: -
RoHS: Unknown
Download Datasheet Visit Manufacturer Site View Pricing & Stock

Specifications

IC Function Gas Flow Meter SOC
Supply Voltage Min 2.3V
Supply Voltage Max 3.6V
IC Package Type TQFN
No. of Pins 40Pins
Operating Temperature Min -40°C
Operating Temperature Max 85°C
Product Range -
Automotive Qualification Standard -
RoHS Phthalates Compliant To Be Advised
MSL MSL 1 - Unlimited
SVHC No SVHC (15-Jan-2018)

Last 6 months Inventory & Pricing History


Alternative Descriptions

Gas Flow Meter Soc, 2.3V-3.6V, Tqfn-40 | Newark Electronics
GAS FLOW METER SOC, 2.3V-3.6V, TQFN-40 | element14
TIME-TO-DIGITAL CONVERTER WITH | Analog Devices

Frequently Asked Questions

Where can I find additional details, specifications and documents for a MAX35104ETL+ ?

Additional datasheets, footprints and schematics for MAX35104ETL+ are listed on our Part Details page. You can also find images and similar parts to MAX35104ETL+ on this page.

What pricing and inventory information can I view?

Distributor pricing and stock information is available for MAX35104ETL+ on our Product Comparison page. Access via the 'View Pricing & Stock' button to view MAX35104ETL+ price breaks, MOQs, lead times, inventory and SKUs from distributors.

Who can I contact for technical support of the product?

Submit any questions directly to the customer support team of the distributor listing the product. For the MAX35104ETL+ you can contact the distributor directly for product support, shipping queries etc.

Is the MAX35104ETL+ RoHS compliant?

This part has not been flagged as RoHS Compliant.

Which authorised distributors for MAX35104ETL+ have stock available?

Authorised distributors including Newark Electronics, element14, Analog Devices and Farnell have stock available or on a lead time for MAX35104ETL+ .

How do I check stock and lead times for all distributors?

Stock availability and lead times will be displayed for MAX35104ETL+ often in real-time on the comparison pages.

What if I can't find stock of MAX35104ETL+ ?

You can fill out our help required form which you can use to request a quote for MAX35104ETL+ from some of our verified obsolescence suppliers. Alternatively, contact us via our web chat in the bottom left of your screen and one of our team will try to help.